Practice Test: Question Set - 20
1. Which of the following refrigerant is highly toxic and flammable?
- (A) Ammonia
- (B) Carbon
dioxide
- (C) Sulphur
dioxide
- (D) R-12
2. The dehumidification process, on the psychrometric chart, is shown by
- (A) Horizontal
line
- (B) Vertical
line
- (C) Inclined
line
- (D) Curved
line
3. The wet bulb temperature at 100% relative humidity is ________ dry bulb temperature.
- (A) Same
as
- (B) Lower
than
- (C) Higher
than
- (D) None
of these
4. The human body feels comfortable when the heat stored in the body is
- (A) Positive
- (B) Negative
- (C) Zero
- (D) None
of these
5. The heat rejection factor (HRF) is given by
- (A) 1 + C.O.P
- (B) 1 - C.O.P.
- (C) 1 +
(1/C.O.P)
- (D) 1 -
(1/C.O.P)
6. In order to collect liquid refrigerant and to prevent it from going to a ________, a device known as accumulator is used at the suction of compressor.
- (A) Compressor
- (B) Condenser
- (C) Expansion
valve
- (D) Evaporator
7. The vertical and uniformly spaced lines on a psychrometric chart indicates
- (A) Dry
bulb temperature
- (B) Wet
bulb temperature
- (C) Dew
point temperature
- (D) Specific
humidity
8. The undesirable property of a refrigerant is
- (A) Non-toxic
- (B) Non-flammable
- (C) Non-explosive
- (D) High
boiling point
9. The process, generally used in summer air conditioning to cool and dehumidify the air, is called
- (A) Humidification
- (B) Dehumidification
- (C) Heating
and humidification
- (D) Cooling
and dehumidification
10. The leakage in a refrigeration system using ammonia is detected by
- (A) Halide
torch
- (B) Sulphur
sticks
- (C) Soap
and water
- (D) All of these
11. The lowest temperature during the cycle in a vapour compression system occurs after
- (A) Compression
- (B) Expansion
- (C) Condensation
- (D) Evaporation
12. In a domestic refrigerator, a capillary tube controls the flow of refrigerant from the
- (A) Expansion
valve to the evaporator
- (B) Evaporator
to the thermostat
- (C) Condenser
to the expansion valve
- (D) Condenser
to the evaporator
13. The refrigerant used in small tonnage commercial machines (hermetically sealed units) is
- (A) Ammonia
- (B) Carbon
dioxide
- (C) Sulphur
dioxide
- (D) R-12
14. When the air is passed through an insulated chamber having sprays of water maintained at a temperature higher than the dew point temperature of entering air but lower than its dry bulb temperature, then the air is said to be
- (A) Cooled
and humidified
- (B) Cooled
and dehumidified
- (C) Heated
and humidified
- (D) Heated
and dehumidified
15. A refrigerant compressor is used to
- (A) Raise
the pressure of the refrigerant
- (B) Raise
the temperature of the refrigerant
- (C) Circulate
the refrigerant through the refrigerating system
- (D) All
of the above
Blogger Comment
Facebook Comment